Service and maintenance
8.2 Error messages
SIMATIC RF360R
84 Configuration Manual, 03/2022, C79000-G8976-C629-02
Flashin
g of the
reader
LED
Block (hex) Error description
--
0xE1FE0400
Initialization error
Transponder is unable to execute the initialization command
Possible causes:
Transponder is defective.
--
0xE1FE0500
The transponder memory is full.
04
0xE1FE0600
RF300: Data storage was not completed correctly for the semaphore procedure.
11
0xE1FE0700
Password error
--
0xE1FE0900
The command is not supported by the transponder.
--
0xE1FE0A00
The transponder is read/write-protected.
--
0xE1FE8100
The transponder is not responding.
--
0xE1FE8200
The transponder password is incorrect. Access is denied.
--
0xE1FE8300
The verification of the written transponder data has failed.
Possible causes:
Transponder is defective.
Transponder is in the limit area.
--
0xE1FE8400
General transponder error
--
0xE1FE8500
The transponder has too little power to execute the command.
Possible causes:
Transponder is in the limit area.