Service and maintenance
8.2 Error messages
SIMATIC RF360R
Configuration Manual, 03/2022, C79000-G8976-C629-02
83
8.2 Error messages
You have the following options for error analysis of the modules:
Via error messages of the reader
Using WBM
Via XML error messages
Via OPC UA error messages
These alternative methods are described below.
8.2.1 Error messages of the reader
Note that, depending on the cause of the error, the status LED "ERROR" (ER) always flash
when error messages occur. The reader LED indicator also flashes for some errors. You can
determine the error via the error codes output by the Ident profile.
The following table lists the error codes.
Table 8- 4 Error messages of the readers
Flashin
g of the
reader
LED
Block (hex) Error description
12
0xE1FE0100
Cannot write to the memory of the transponder.
Possible causes:
Transponder memory is defective.
EEPROM transponder was written too frequently and has reached the end of its service life.
02
0xE1FE0200
Presence error
The transponder is no longer within the transmission window of the reader. The command was
not or only partially executed.
Read command: There is no valid data in "IDENT_DATA".
Write command: The transponder that has just left the antenna field contains an incomplete
data record.
Possible causes:
Operating distance between reader and transponder is not being maintained.
Configuration error: The data record to be processed is too large (in dynamic mode).
13
0xE1FE0300
Address error
The address range of the transponder has been exceeded.
Possible causes:
Start address of the command start has been incorrectly set.
Wrong transponder type
The area to be written to is write-protected.