Operating the software
5.4 The tabs of the RF620R/RF630R readers
SIMATIC RF-DIAG
56 Operating Manual, 09/2012, C79000-G8976-C292-01
● Stop
Stopping the recording
● Deleting the display
Existing values from the last recording are deleted.
A progress bar indicates that the recording is active.
List of identified transponders
After you have started recording, all the transponders identified by the reader are listed in the
table.
Table 5- 8 Displayed properties of the recognized transponders
Property Description
OK Symbol indicating whether the transponder was detected as valid by the reader.
If the reader is operating in Smoothing mode, the transponder needs to be
detected Observed Threshold number of times.
Tag ID EPC ID of the detected transponder
Antenna Antenna with which the transponder was detected. Only one antenna is ever
displayed here. With this display, you cannot recognize the antenna or antennas
that detected the transponder or whether several antennas detected the
transponder.
RSSI RSSI value with which the transponder was last read.
RSSI min Minimum RSSI value of the transponder. Calculated over all successful
inventories.
RSSI max Maximum RSSI value of the transponder. Calculated over all successful
inventories.
Mean RSSI Average RSSI value of the transponder.
Reads Number of successful inventories of the transponder.
LastObs. Time stamp when the transponder was last read.
DT glimpsed Time that has elapsed in [ms] between the first and last successful transponder
read.