8.8 Active Management Technology (AMT)
SIMATIC IPC427E
134 Operating Instructions, 09/2017, A5E37454814-AB
Settings in the MEBx
1. Use the arrow keys to select "MEBx" and confirm with the <Enter> key.
2. Select "MEBx Login".
3. Enter the default password "admin".
Change the password. The new password must comprise:
At least eight characters
At least one upper case letter
At least one lower case letter
At least one number
At least one special character (! @ # $ % ^ & *)
The underscore "_" and space characters are valid in the string but do not increase the
complexity of the password.
Note
If the password is no longer available, you must reset the Intel®
AMT to the default
settings, see
Resetting the Intel® AMT to the default settings and disabling AMT
(Page
135).
Backup the password to protect it against loss.
4. Switch to the "Intel (R) AMT Configuration" submenu and enable "Manageability Feature
Selection".
5. Switch to the "Intel(R) ME General Settings" submenu and enable access via the network
with "Activate Network Access".
6. Confirm the dialogs that appear with "Y".
Drivers are automatically installed once as required in the subsequent restart.