EasyManuals Logo

Siemens SIMATIC IPC427E User Manual

Siemens SIMATIC IPC427E
164 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
Extended device functions
5.3 Enhanced Write Filter (EWF)
SIMATIC IPC427E
54 Operating Instructions, 09/2017, A5E37454814-AB
Setting EWF
The following programs can be used to install, enable or disable the EWF:
EWFMGR.EXE
SIMATIC IPC EWF Manager.
The SIMATIC IPC EWF Manager is preinstalled and included on the supplied USB stick
(DocuAndDrivers\Drivers).
Start the SIMATIC IPC EWF Manager as follows:
"Start > All Programs >Siemens Automation > SIMATIC > EWF Manager > EWF
Manager"
Configure the SIMATIC IPC EWF Manager as follows:
"Start > All Programs > Siemens Automation > SIMATIC > EWF Manager > EWF
Settings"
or
Click the "SIMATIC IPC EWF Manager" icon in the system tray.
The following functions are available:
Function
Command
Write-protect drive C: Power on
ewfmgr c: -enable
Write-protect drive C: disable: the modified data are
applied
ewfmgr c: -commitanddisable
Modified data on drive C: apply
ewfmgr c: -commit
Display information about the EWF drive
ewfmgr c:
Display help
ewfmgr /h
Note
The EWF commands affecting the write protection do not become active until after the next
booting process.
Note
The EWF command ewfmgr c:
-
commitanddisable
may not be used with the option -
live
.

Table of Contents

Other manuals for Siemens SIMATIC IPC427E

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC IPC427E and is the answer not in the manual?

Siemens SIMATIC IPC427E Specifications

General IconGeneral
BrandSiemens
ModelSIMATIC IPC427E
CategoryIndustrial PC
LanguageEnglish

Related product manuals