Device maintenance and repair
7.4 Removing and installing hardware
SIMATIC IPC547E
Operating Instructions, 02/2014, A5E32317120-AB
93
7.4.5
Removing module of the redundant power supply
Execute this step if one or both power supply modules must be replaced.
Requirement
The device is fully disconnected from the mains voltage, see chapter "Switching off the
device (Page 53)".
T10 screwdriver
Procedure
1.
Remove the screws that are marked in the
figure below.
2.
Pull out the power supply module from the
enclosure using the handle.
7.4.6
Removing the enclosure of the redundant power supply from the module
Requirement
The device is fully disconnected from the mains voltage, see chapter "Switching off the
device (Page 53)".
The device is open, see the chapter "Open the device (Page 62)".
The module of the redundant power supply has been removed, see chapter "Removing
module of the redundant power supply (Page 93)".
T10 screwdriver