Commissioning
7.4 Notes on operation
SIMATIC IPC647C
48 Operating Instructions, 12/2010, A5E02669337-02
RAID system management functions
The pre-installed RAID system software offers enhanced functionality for RAID system
operation and management. Start the SW
by selecting "Start > Programs > Intel Rapid Storage Technology.
Figure 7-2 Example
The "Manage -> Advanced" command returns details of the RAID volumes.
Use the command "Help > System Report > Save" to create a report with details of the RAID
volumes.
NOTICE
The RAID status entries are returned by default in the Windows event view and in the log
file of the program.
A hard drive can be synchronized at operating system level if a fault is detected. It may take
a very long time (hours, in case of a high hard disk load even days) to synchronize a new
hard disk in the background, depending on its size and on the system load.
The safe RAID Level 1 system state is achieved again only after synchronization is
completed.

Table of Contents

Other manuals for Siemens Simatic IPC647C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic IPC647C and is the answer not in the manual?

Siemens Simatic IPC647C Specifications

General IconGeneral
BrandSiemens
ModelSimatic IPC647C
CategoryIndustrial PC
LanguageEnglish

Related product manuals