Commissioning
7.4 Notes on operation
SIMATIC IPC647C
Operating Instructions, 12/2010, A5E02669337-02
49
Comments about faults
NOTICE
Input delay
System load may briefly increase due to synchronization when a hard disk has failed,
depending on processor load and current hard disk activity.
Execution of keyboard and touch screen commands may be briefly delayed in extreme
situations.
Before you replace the defective hard disk, create a backup copy of the system.
Replacing a faulty drive in a RAID array
Replace defective RAID drives with a new drive in order to achieve safe RAID1. The RAID
software reports the faulty drive and returns details of the operable hard drive.
The working disk is displayed by the BIOS with a port number or by the RAID software with a
device port number. To view details about each drive, move the mouse cursor over the drive
and press the right mouse button. A pop-up window is then activated.
Figure 7-3 Example
The functioning drive can be located using the following pictures and tables.
The table and information below apply only to the delivery state of the device, that is if no
changes or expansions were made.

Table of Contents

Other manuals for Siemens Simatic IPC647C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens Simatic IPC647C and is the answer not in the manual?

Siemens Simatic IPC647C Specifications

General IconGeneral
BrandSiemens
ModelSimatic IPC647C
CategoryIndustrial PC
LanguageEnglish

Related product manuals