EasyManua.ls Logo

Siemens SIMATIC Rack PC 840 - Page 130

Siemens SIMATIC Rack PC 840
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hardware Information
7-22
SIMATIC Rack PC 840 Manual
A5E00104826-03
Port for Floppy Disk Drive, X26
This port is intended for the connection of a standard floppy disk drive. The
maximum connection length of the data cable may not exceed 40 cm.
Pin No. Designation Description Input / Output
1 GND Ground -
2 DENSEL High Density Disk selection Output
3 GND Ground -
4 - Unassigned -
5 GND Ground -
6 DRAME0 Data rate signal Output
7 GND Ground -
8 INDEX_N Index hole recognition Input
9 GND Ground -
10 MOT_N0 Activate motor 0 Output
11 GND Ground -
12 DS_N1 Drive 1 selection
13 GND Ground -
14 DS_N0 Drive 0 selection
15 GND Ground -
16 MOT_N0 Activate motor 1 Output
17 GND Ground -
18 DIR_SL_N Step motor direction Output
19 GND Ground -
20 STEP_N Step motor pulse
21 GND Ground -
22 WR_DAT_N Write data signal Output
23 GND Ground -
24 WR_GAT_N Enable data signal Output
25 GND Ground -
26 TRACK_N0 Track 0 signal Input
27 GND Ground -
28 WR_PRT_N Write protection signal Input
29 GND Ground -
30 RD_DAT_N Read Data signal Input
31 GND Ground -
32 SIDE_1_N Page selection Output
33 MED_ID1 High Density Disk recognition Input
34 DCHG_N Disk change display Input