Programming via OPC UA
10.2 OPC UA variables
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
127
Table 10- 12 Client
Path
Root/Objects/DeviceSet/Read_point_x/RuntimeParameters/Diag
nosis/LastAccess/Client
Data type
String
Access
R
Description
Diagnostics on the last transponder access
Indicates the client interface via which the last transponder ac-
cess to this read point took place.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Possible values
PNIO: Access via PROFINET
OPCUA: Access via OPC UA
WBM: Access via WBM
XML1: Access via the XML channel 1
XML2: Access via the XML channel 2
XML3: Access via the XML channel 3
XML4: Access via the XML channel 4
EIP: Access via EtherNet/IP
PB: Access via PROFIBUS
READPOINT: internal access via the read point
The read points of the device can scan for transponders in-
dependently. This is the case, for example, when at least one
user application has started an asynchronous scan command
or when a configured trigger was started with RF600. These
events can also overlap in which case they can no longer be
clearly assigned. In this case, the value "READPOINT" is al-
ways used instead.