Programming via OPC UA
10.2 OPC UA variables
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
128 Operating Instructions, 04/2020, C79000-G8976-C512-03
Table 10- 13 Command
Path
/Root/Objects/DeviceSet/Readpoint_x/RuntimeParameters/Diagn
osis/LastAccess/Command
Data type
String
Access
R
Description
Diagnostics on the last transponder access
Outputs the command executed during the last transponder
access operation.
The prerequisite is that the "Parallel" or "Diagnostics" option is
set in the WBM.
Possible values
Depending on the client interface used:
PNIO, PB, EIB
(Ident profile):
INVENTORY
WRITE-ID
KILL-TAG
LOCK-TAG-BANK
PHYSICAL-READ
PHYSICAL-WRITE
FORMAT
TAG-STATUS
GET
PUT
NEXT
PNIO, PB (FB 45):
WRITE
READ
INIT
MDS-STATUS
OPC UA:
Scan
ReadTag
WriteTag
KillTag
LockTag
SetTagPassword
Read
Write
WBM, XML:
readTagIDs
writeTagID
readTagMemory
writeTagMemory
killTag
lockTagBank
getTagStatus
READPOINT: