Configuring
6.2 Configuration via PROFINET IO
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
Operating Instructions, 04/2020, C79000-G8976-C512-03
55
"Module parameters" parameter group
In this parameter group, you can configure all module-specific parameters of the
communication module.
Table 6- 3 Parameters in the "Module parameters" parameter group
Diagnostic interrupt Off
On Switching diagnostic interrupt messages of the
communication module on and off.
Parameter group "Module parameters > General parameters" of the submodules (connected readers)
In this parameter group, you can configure all module-specific parameters of the connected
readers. Please note that some of the following parameters are module-specific. For some
module types, not all parameters are displayed.
Depending on the Ident device that is connected to the respective interface (X21-X24), you
must use the matching submodule.
If no device is connected to interface X21, you need to assign an "Empty" module to this
interface.
Table 6- 4 Parameters of the parameter group "Module parameters > General parameters" of the submodules (connect-
ed readers)
User mode Ident profile/RFID stand-
ard profile
FB 45
Ident profile/RFID
standard profile
With this parameter, you select the block:
• Ident profile/RFID standard profile:
Single tag / multitag mode. The program
block for the Ident profile is used in the con-
troller.
• FB 45:
Single tag mode. FB 45 is used in the con-
MOBY mode RF200/RF300/RF600;
MV400/MV500; MOBY
U/D normal addr.
RF200/RF300/RF60
0; MV400/MV500;
MOBY U/D normal
addr.
With this parameter, you set the mode of the
communication module.
• RF200/RF300/RF600; MV400/500; MOBY
U/D normal addr.
Normal addressing: The transponder is ad-
dressed with physical addresses.
Transmission
speed
19.2 kBd
57.6 kBd
115.2 kBd
921.6 kBd
115.2 kBd With this parameter, you set the data transmis-
sion speed between the communication module
and the reader.
When an optical reader is connected: The
transmission speed selected here must match
the transmission speed selected for the reader.