Configuring
6.2 Configuration via PROFINET IO
SIMATIC RF185C, RF186C, RF188C, RF186CI, RF188CI
56 Operating Instructions, 04/2020, C79000-G8976-C512-03
Diagnostics
messages
None
Hard errors
Hard/soft errors
None With this parameter, you determine the extent
to which the reader-related diagnostic interrupt
messages are to be reported.
• None:
No alarms are generated.
• Hard errors:
Critical hardware errors/faults are reported
by the S7 diagnostics.
• Hard/soft errors:
Critical hardware faults and errors occurring
when processing commands are reported
IO mode
1)
Input
Output
IO-Link
Input You use this parameter to specify the mode of
the I/O interface of the communication module:
• Input:
Single digital input
• Output:
Single digital output
• IO-Link:
Mode for connection of an IO-Link device
with digital inputs/outputs.
1)
This parameter is only included for CI communication modules.