EasyManua.ls Logo

Siemens SIMATIC S7-1200

Siemens SIMATIC S7-1200
364 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motion control is easy
10.5 Motion control instructions
Easy Book
Manual, 03/2014, A5E02486774-AF
237
Override response
The MC_CommandTable task can be
aborted by the following motion control
tasks:
MC_Home Mode = 3
MC_Halt
MC_MoveAbsolute
MC_MoveRelative
MC_MoveVelocity
MC_MoveJog
MC_CommandTable
The new MC_CommandTable task aborts
the
following active motion control tasks:
MC_Home Mode = 3
MC_Halt
MC_MoveAbsolute
MC_MoveRelative
MC_MoveVelocity
MC_MoveJog
MC_CommandTable
The current motion control job with the
launch of the first "Positioning Relative",
"Positioning Absolute", "Velocity setpoint"
or "Halt" command
10.5.11
MC_ChangeDynamic (Change dynamc settings for the axis) instruction
Table 10- 27 MC_ChangeDynamic instruction
LAD / FBD
SCL
Description
"MC_ChangeDynamic_DB"(
Execute:=_bool_in_,
ChangeRampUp:=_bool_in_,
RampUpTime:=_real_in_,
ChangeRampDown:=_bool_in_,
RampDownTime:=_real_in_,
ChangeEmergency:=_bool_in_,
EmergencyRampTime:=_real_in_,
ChangeJerkTime:=_bool_in_,
JerkTime:=_real_in_,
Done=>_bool_out_,
Error=>_bool_out_,
ErrorID=>_word_out_,
ErrorInfo=>_word_out_);
Changes the dynamic settings of
a motion control axis:
Change the ramp-up time
(acceleration) value
Change the ramp-down time
(deceleration) value
Change the emergency stop
ramp-down time (emergency
stop deceleration) value
Change the smoothing time
(jerk) value
1
STEP 7 automatically creates the DB when you insert the instruction.
2
In the SCL example, "MC_ChangeDynamic_DB " is the name of the instance DB.