Glossary
CPU 31xC and CPU 31x, Technical data
Glossary-12 Manual, Edition 08/2004, A5E00105475-05
Nesting depth
A block can be called from another by means of a block call. Nesting depth is referred to as
the number of simultaneously called code blocks.
Network
A network is a larger communication system that allows data exchange between a large
number of nodes.
All the subnets together form a network.
A network consists of one or more interconnected subnets with any number of nodes.
Several networks can exist alongside each other.
Non-isolated
The reference potential of the control and on-load power circuits of non-isolated I/O modules
is electrically interconnected.
OB
See Organization blocks
OB priority
The CPU operating system distinguishes between different priority classes, for example,
cyclic program execution, process interrupt controlled program processing. Each priority
class is assigned organization blocks (OBs) in which the S7 user can program a response.
The OBs are assigned different default priority classes. These determine the order in which
OBs are executed or interrupt each other when they appear simultaneously.
Operating state
SIMATIC S7 automation systems know the following operating states: STOP, START, RUN.
Operating system
The CPU OS organizes all functions and processes of the CPU which are not associated to
a specific control task.
See CPU
Organization blocks
Organization blocks (OBs) form the interface between CPU operating system and the user
program. OBs determine the sequence for user program execution.
Parameters
1. Variable of a STEP 7 code block
2. Variable for declaring module response (one or several per module). All modules have a

Table of Contents

Other manuals for Siemens SIMATIC S7-300 Module data

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMATIC S7-300 Module data and is the answer not in the manual?

Siemens SIMATIC S7-300 Module data Specifications

General IconGeneral
SeriesS7-300
ManufacturerSiemens
Protection ClassIP20
SystemSIMATIC S7-300
Digital InputsVaries by module
Digital OutputsVaries by module
Analog InputsVaries by module
Analog OutputsVaries by module
Central Processing UnitVaries by CPU model
Supply Voltage24V DC or 120/230V AC
CPU TypeVaries (e.g., CPU 312, CPU 315, etc.)
MemoryVaries by CPU model
Communication InterfacesMPI, PROFIBUS
Programming LanguagesLAD, FBD, STL, SCL, GRAPH
Operating Temperature0°C to 60°C
Storage Temperature-40°C to 70°C
Relative Humidity10% to 95% (non-condensing)