Fail-Safe Blocks
Fail-Safe Systems
A5E00085588-03
8-37
8.4.2 F_I_FI
Function
This block converts the INT data type into the corresponding F_INT F data type.
This enables signals formed in the standard program section to be processed
further in the safety program section following a plausibility check (to be added by
the user with F-block F_LIM_I, for example).
I/Os
Name Data Type Explanation Default
Input:
IN INT Input variable 0
Output:
OUT F_INT Output variable 0
Error Handling
None