Fail-Safe Blocks
Fail-Safe Systems
A5E00085588-03
8-39
8.4.4 F_TI_FTI
Function
This block converts the TIME data type into the corresponding F_TIME F data
type. This enables signals formed in the standard program section to be further
processed in the safety program section following a plausibility check (to be added
by the user with F-block F_LIM_TI, for example).
I/Os
Name Data Type Explanation Default
Input:
IN TIME Input variable T#0 ms
Output:
OUT F_TIME Output variable T#0 ms
Error Handling
None