SIMATIC VS710
Quick Reference Guide
28
SIMATIC VS 710
A5E00032597-02
Characteristic Technical Specifications
Climatic Conditions
Temperature
S Operation
S Storage/trans-
port
Tested according to IEC 68-2-1, IEC 68-2-2
± 0 °C to + 50 °C
Rate of temperature change max. 10 °C/h
-20 °C to +70 °C
Rate of temperature change max. 20 °C/h
Relative humidity
S Operation
S Storage/trans-
port
Tested according to IEC 68-2-3
5% to 95% at 25°C (no condensation)
5% to 95% at 25°C (no condensation)
Atmospheric
pressure
S Operation
S Storage/trans-
port
1080-795 hPa (¢ -1000 m to +2000 m)
1080-660 hPa (¢ -1000 m to +3500 m)
Mechanical Environmental Conditions (without lens)
Vibration
S Operation
S Storage/trans-
port
Tested according to IEC 68-2-6
10 to 58 Hz, amplitude 0.075 mm
58 to 500 Hz, acceleration 9.8 m/s
2
5 to 9 Hz, amplitude 3.5 mm
9 to 500 Hz, acceleration 9.8 m/s
2
Shock
S Operation
S Storage/trans-
port
Tested according to IEC 68-2-27/29
Semi-sinusoidal: 100 m/s
2
(10 g),
16ms, 100 shocks
Semi-sinusoidal: 700 m/s
2
(70 g),
6ms, 3 shocks
Semi-sinusoidal: 250 m/s
2
(25 g),
6ms, 1000 shocks
Note
The absolute brightness values of the image may vary slightly, depending
on the physical properties of the CCD chip and the temperature range.