Do you have a question about the Siemens SIMOCODE pro V EIP and is the answer not in the manual?
Product designation | SIMOCODE pro V EIP |
---|---|
Communication Protocol | EtherNet/IP |
Supply voltage | 24 V DC |
Digital inputs | Up to 8 |
Analog outputs | Up to 2 |
Storage temperature | -40 to +70 °C |
Protection Class | IP20 |
Width | 45 mm |
Height | 100 mm |
Weight | Approx. 0.5 kg |
Product function | Motor management and control |
Analog inputs | Up to 2 |
Operating temperature | -20 to +60 °C |
Relative humidity | 5 to 95% (non-condensing) |
Highlights benefits like reduced cabling, decentralized automation, increased availability, and modularity.
Lists multifunction electronic full motor protection features up to 820 A, including overload and thermistor protection.
Details integrated motor control functions replacing extensive hardware interlocks.
Explains communication via PROFIBUS, PROFINET, Modbus RTU, and EtherNet/IP.
Provides a checklist to help select the optimum SIMOCODE pro device series based on requirements.
Details the fundamental basic units (BU) for SIMOCODE pro systems, including types and supply voltages.
Explains the optional operator panel with display for showing measured values, operating data, and diagnostics.
Covers prerequisites, parameterization methods, and commissioning options for SIMOCODE pro.
Step-by-step guide for commissioning SIMOCODE pro with PROFIBUS, including address setting and diagnostics.
Steps for commissioning SIMOCODE pro with PROFINET, including IP parameters and device name setting.
Provides the sequence for commissioning SIMOCODE pro V Modbus basic units and setting communication parameters.
Instructions for saving parameters to a memory module or SIMOCODE ES file and vice versa.
Guides on replacing basic units, expansion modules, decoupling modules, and DM-F modules.
Details error buffer, event memory, and troubleshooting for alarms, faults, and system events.
Details module integration for motor protection functions like overload and thermistor protection.
Provides operating instructions and guidance on setting the rated motor current and trip class.
Covers short-circuit protection for coordination types and general system tests for motor protection.
Provides safety guidelines for DM-F modules, electrical isolation, and permissible ambient temperature ranges.
Explains dry-running protection using active power monitoring, including module integration and information standards.
Provides operating instructions and general information for installing and commissioning dry-running protection.
Guides on setting parameters like trip level, delay time, and bridging time for dry-running protection.