EasyManua.ls Logo

Siemens SIMOCODE pro V MR User Manual

Siemens SIMOCODE pro V MR
408 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SIMOCODE pro
Industrial Controls
Motor management and
control devices
SIMOCODE pro
System Manual
05/2019
A5E40507475002A/RS
-AD/004
Introduction
1
Advantages/benefits/configuration
with SIMOCODE pro
2
Areas of application
3
Features
4
Overview of functions
5
Check list for selecting a device
series
6
An overview of system components
7
Description of system components
8
Compartment identification
9
Accessories
10
3UF50 compatibility mode
11
Mounting, wiring, connecting, system
interfaces, configuration guidelines
12
Commissioning, service,
troubleshooting
13
Safety and commissioning
information for Ex areas
14
Technical data
15
CAx data, dimension drawings
16
List of abbreviations
A

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE pro V MR and is the answer not in the manual?

Siemens SIMOCODE pro V MR Specifications

General IconGeneral
TypeSIMOCODE pro V MR
Protection ClassIP20
Control Voltage / Supply voltage / Rated operational voltage24 V DC
Communication InterfacePROFIBUS DP, PROFINET
Protection FunctionsOverload, phase failure, locked rotor, ground fault
Ambient temperature range-25°C to +60°C

Summary

Advantages/benefits/configuration with SIMOCODE pro

2.1 Advantages/benefits

Reduced cabling, decentralized automation, increased plant availability, modularity, and cost savings.

Areas of application

Protection and control of motors

Used in automated processes for motor protection, including hazardous areas.

Features

Multifunction, electronic full motor protection

Comprehensive motor feeder protection with delayable, multi-level functions.

Overview of functions

5.1 Protection functions

Covers overload, thermistor, phase failure, stalled rotor, and dry-running protection.

5.3 Safety-oriented tripping

Supports safety-related tripping via hardware or communication bus using fail-safe modules.

Check list for selecting a device series

Description of system components

8.1 Basic units (BU)

Fundamental components containing the processor for all system functions.

Compartment identification

3UF50 compatibility mode

11.1 Application, Win-SIMOCODE-DP converter

Enables replacement of SIMOCODE-DP devices with SIMOCODE pro V PB without configuration changes.

Mounting, wiring, connecting, system interfaces, configuration guidelines

12.1 Mounting

Provides instructions on attaching basic units, expansion modules, and decoupling modules.

12.2 Wiring, connecting

Details terminal assignments and cable specifications for various modules.

12.3 System interfaces

Explains connectivity of system components via interfaces and provides connection examples.

Commissioning, service, troubleshooting

13.1 General information about commissioning and service

Outlines prerequisites and parameterization methods for commissioning and servicing.

13.2 Commissioning

Step-by-step guides for commissioning with PROFIBUS, PROFINET, and Modbus.

Safety and commissioning information for Ex areas

Technical data

Glossary

Related product manuals