EasyManua.ls Logo

Siemens SIMOCODE pro V - Table of Contents

Siemens SIMOCODE pro V
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Table of contents
Blocking Protection for Pumps with SIMOCODE pro V
Article ID: 109478058, V2.0, 09/2020
3
© Siemens AG
2020 All rights reserved
Table of contents
Legal information ......................................................................................................... 2
1 Introduction ........................................................................................................ 4
1.1 Overview............................................................................................... 4
1.2 Delimitation ........................................................................................... 5
1.3 Required knowledge ............................................................................. 5
1.4 Components used ................................................................................ 6
2 Operating principle ............................................................................................ 9
2.1 Logic blocks in use ............................................................................. 10
2.2 Explanation of the logic ...................................................................... 12
2.2.1 Embedding ......................................................................................... 12
2.2.2 Detecting faults in the conveying flow ................................................ 13
2.2.3 Switching on via the control station .................................................... 14
2.2.4 Shutting off via the control station or in the event of a fault ............... 15
2.2.5 Manual reversal in the other direction of rotation ............................... 16
2.2.6 Reversal in the opposite direction when conveying fault has
been detected ..................................................................................... 17
2.2.7 Fault shutdown after defined number of reversals ............................. 17
2.2.8 Drive start after fault shutdown .......................................................... 17
2.2.9 Resetting the fault counter during operation ...................................... 18
2.2.10 Blockage in the opposite direction ..................................................... 18
2.2.11 Cyclic communication with the controller ........................................... 18
3 Engineering ...................................................................................................... 20
3.1 Hardware configuration ...................................................................... 20
3.1.1 Basic unit (BU) ................................................................................... 21
3.1.2 Detecting irregularities in the conveying flow ..................................... 21
3.1.3 Clearing blockages in the conveying flow .......................................... 21
3.1.4 Digital module (DM) ............................................................................ 21
3.1.5 Operator panel (OP) ........................................................................... 21
3.1.6 Communication with a PLC ................................................................ 21
3.2 Installation and commissioning .......................................................... 22
3.2.1 Hardware installation .......................................................................... 22
3.2.2 Installing the software ......................................................................... 23
3.2.3 Downloading configuration and parameterization to the
SIMOCODE pro V PN basic unit ........................................................ 24
3.2.4 Commissioning ................................................................................... 27
3.3 Parameterization ................................................................................ 28
3.3.1 Creating the hardware configuration .................................................. 29
3.3.2 Parameter assignment for the SIMOCODE pro V PN ....................... 31
3.3.3 Compile parameterization .................................................................. 53
3.4 Operation ............................................................................................ 54
3.4.1 General remarks on Monitoring and Control ...................................... 54
3.4.2 Scenarios ........................................................................................... 59
4 Useful information ........................................................................................... 62
4.1 Time stamping .................................................................................... 62
5 Appendix .......................................................................................................... 63
5.1 Service and support ........................................................................... 63
5.2 Links and literature ............................................................................. 64
5.3 Change documentation ...................................................................... 64

Related product manuals