9.2.3.4 Installing the labyrinth sealing ring
The labyrinth sealing ring is the last component to be fitted when fitting the roller-contact
bearing. It ensures degree of protection IP65 and prevents the penetration of dirt and foreign
bodies into the roller-contact bearing.
1. Apply a soluble adhesive to the three set screws such as Loctite 243) and screw them
partially into the labyrinth sealing ring.
2. Apply an corrosion protection paint to the shaft in the area of the labyrinth sealing ring.
3. Warm up the labyrinth sealing ring. Push the labyrinth sealing ring to approx. 3 mm before
the bearing cover before the paint or adhesive cures on the set screws.
3mm
Figure 9-5 Position the set screws for the labyrinth sealing ring on the outer bearing cover
4. Locate the labyrinth sealing ring in position by screwing the set screws in. Check that the
tips of the set screws engage with the keyway with a short axial movement.
The correct axial position is obtained when the locating setscrews screwed into the keyway
engage.
9.2.3.5 Fitting V ring for roller bearing seal
Requirement
The roller bearing is already fitted.
Maintenance
9.2 Corrective Maintenance
SIMOTICS HV M 1RN76308PR900CG0-Z
Operating Instructions 07/2018 105