4.6 Interlock circuit for anti-condensation heating
If the anti-condensation heating is operated while the machine is running, this can increase
the temperatures inside the machine.
Install an interlock circuit that switches off the anti-condensation heating once the main
machine is switched on.
Only switch on the anti-condensation heating after the machine has been switched off.
See also
Switching on with the anti-condensation heating active (Page 78)
4.7 Space requirements
Ensure that there is sufficient space where the motor is to be installed so that when required,
the air-to-water exchanger can be removed and installed.
4.8 Noise emission
Excessive sound pressure levels can lead to hearing impairment or hearing loss.
When assessing the noise level of the system, make due allowance for the noise emissions
from the machine.
If necessary, take suitable noise protection measures for personnel.
4.9 Voltage and frequency fluctuations during line operation
If nothing else is stamped on the rating plate, the permissible voltage fluctuation is ±5 % and
the permissible frequency fluctuation is ±2 %, corresponding to range A in IEC / EN 60034‑1.
Permissible fluctuations that go beyond this are stamped on the rating plate.
Under operating conditions a machine may sometimes have to be operated outside the limits
of range A.
Exceeding the permissible tolerances for voltage and frequency can lead to an
impermissibly high temperature rise of the winding. This can result in long-term damage to
the machine.
Limit exceptions of this sort with regard to the values that arise, how often, and for how long
they occur.
Where possible and within a reasonable time take corrective actions such as reducing the
power. Such actions can avoid thermal ageing leading to a reduction in the service life of
the machine.
Preparations for use
4.6 Interlock circuit for anti-condensation heating
SIMOTICS HV M 1RN76308PR900CG0-Z
Operating Instructions 07/2018 25