Operation
8.1 Safety instructions for operation
1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355
100 Operating Instructions, 06/2018, A5E44455710A
NOTICE
Risk of corrosion due to condensation
If the machine and/or ambient temperatures fluctuate, this can result in condensation inside
the machine.
If available, remove the drain plugs or drain screws to drain the water depending on the
ambient and operating conditions.
If available, re-attach the drain plugs or drain screws.
If the motor is equipped with drain plugs, then the water can drain away by itself.
Switching on the machine with anti-condensation heating (optional)
CAUTION
Machine overheating
Minor injury or material damage can occur if you do not observe the following:
If available, switch off the anti-condensation heating each time before switching on.
See also
Converter operation (Page 47)
Explosion hazard from hybrid mixtures
Hybrid mixtures are mixtures of flammable dusts with explosive gas/air atmospheres which
can together create a dangerous explosive atmosphere if they occur at the same time.
Changes can arise in the safety characteristics here, such as a change in the zonal
classification, increase in the explosion pressure, reduction in the minimum ignition energy
and a reduction in the maximum temperatures to be observed.
An explosion can result. This can result in death, serious injury or material damage.
For this reason, the relative characteristics must be considered both for gas (zones 0, 1
and 2) and for dust (zones 20, 21 and 22) where hybrid mixtures arise. It is necessary for
a competent assessor to determine in the individual case whether the parameters
determining ignition are unfavorably affected in a particular hybrid mixture.
Motors with dual plates for G (“Gas”) and D (“Dust”) may only be used where these two
occur after prior examination of the properties of the hybrid mixtures by the user.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOTICS XP 1MB1 series and is the answer not in the manual?

Siemens SIMOTICS XP 1MB1 series Specifications

General IconGeneral
BrandSiemens
ModelSIMOTICS XP 1MB1 series
CategoryEngine
LanguageEnglish

Related product manuals