Maintenance   
9.3 Corrective maintenance 
  1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355 
132  Operating Instructions, 06/2018, A5E44455710A 
●  Use a suitable tool to pull off the fan (puller). 
●  Locate the arms of the pulling tool in the breakout openings and slightly tension the 
pressure screw of the tool. 
●  For fans with snapping mechanisms, simultaneously release the two snap-in lugs of the 
fan from the annular shaft groove. 
Keep the snap-in lugs in this position. 
●  Uniformly withdraw the fan from the shaft by turning the pressure screw of the pulling tool. 
●  Do not apply any hammer blows to avoid damaging the rotor shaft, the fan and the 
bearings. 
●  Order the appropriate new parts if damaged. 
 
Metal fan disassembly 
Metal fan
 
●  Remove the locking ring. 
●  Use a suitable tool to pull off the fan (puller). 
●  Locate the arms of the pulling tool in the openings in the fan in the vicinity of the hub. 
●  Alternatively, place the pulling tool at the outer edge of the fan plate. 
●  Uniformly withdraw the fan from the shaft by turning the pressure screw of the pulling tool. 
●  Do not apply any hammer blows to avoid damaging the rotor shaft, the fan and the 
bearings. 
●  Order the appropriate new parts if damaged. 
 
●  Take care not to damage the snapping mechanisms on fans that are equipped with these. 
●  To ensure this, the fans should be heated to a temperature of approximately 50 °C 
around the area of the hub. 
●  If any damage is caused, request new parts. 
 
Cable entries, sealing plugs and thread adapters 
All cable entries and sealing plugs must be approved for use in the respective hazardous 
zone. 
●  Any openings that are not being used must be sealed using the appropriate certified 
sealing plugs. 
●  Please observe the manufacturer's specifications when fitting cable entries. 
Note the following when mounting: 
●  Avoid damaging the cable jacket. 
●  Adapt the tightening torques to the cable jacket materials.