Maintenance   
9.3 Corrective maintenance 
  1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355 
126  Operating Instructions, 06/2018, A5E44455710A 
 
Explosion hazard due to improper maintenance  
If repairs to the anti-condensation heating are not carried out correctly, e.g. if unauthorized 
or untested spare parts are used, this can result in explosions during operation in a 
potentially explosive gaseous atmosphere. This can result in death, serious injury, or 
material damage.  
•  Repairing and mounting the anti-condensation heating and the subsequent routine 
testing must always be undertaken by experts from the service center (Page 163), 
because this work requires extensive specialist knowledge. 
•  Only authorized and tested spare parts may be used. 
 
Note 
Before commencing removal, you should mark how each of the fastening elements has been 
assigned, as well as how internal connections are arranged. This simplifies subsequent 
reassembly.
 
If possible, assemble the machine on and alignment plate. This ensures that the mounting 
feet surfaces are all on the same plane.  
Avoid damaging the windings protruding out of the stator enclosure when assembling the 
end shield. 
 
Sealing measures 
Sealing measures
 
1.  For 1MB10, shaft heights 100...160, apply the appropriate liquid sealant, e.g. Fluid-D or 
Hylomar to the centering edge. 
2.  Check the terminal box seals, and if required, replace these. 
3.  Repair any damage to the paint, also to screws/bolts. 
4.  Take the necessary measures to ensure compliance with the applicable degree of 
protection. 
5.  Do not forget the foam rubber cover in the cable entry. Completely seal the holes, and 
ensure that cables do not come into contact with sharp edges.