8.1 Safety instructions for operation 
  1LA5/6/7/9, 1LG4/6, 1MA6/7, 1MB..1/2/3/4/5 - SH 63 ... 355 
102  Operating Instructions, 06/2018, A5E44455710A 
 
Risk of explosion due to excessive bearing temperature  
The surface temperature cannot be maintained within maximum permissible limits if the 
bearing becomes too hot. The dust can ignite, resulting in an explosion. This can result in 
death, serious injury, or material damage. 
•  Always check the bearing temperatures. 
•  In addition to the current-dependent overload protection device located in the three 
phases of the connecting cable, we recommend that you also monitor the temperature 
rise in the machine with the aid of the temperature sensors built into the stator winding. 
•  You will find the alarm and shutdown temperatures in the Technical Data. 
To ensure problem-free machine cooling, the air ducts (ventilation grilles, channels, cooling 
fins, tubes) must be free of pollution. 
 
 
Risk of explosion when cleaning with compressed air 
If you clean the machine with compressed air, plastic components may become statically 
charged and ignite a potentially explosive atmosphere; an explosion can occur. This can 
result in death, serious injury or material damage. 
•  Do not use compressed air to clean motors when installed in hazardous zones! 
 
Safety instructions relating to ventilation and cooling 
Forced ventilation (optional): Type of cooling IC 416 in accordance with EN / IEC 60034-6 
 
Operating the machine without external fan results in overheating. This may result in death, 
personal injury and material damage. 
•  Never commission the machine without an external fan. 
 
Risk of injury when touching the fan 
There is a risk of injury at machines equipped with a fan cover (e.g. on machines in the 
textile industry), as the fan is not completely touch protected. 
•  Do not touch the rotating fan. 
•  Do not put your fingers into the larger air discharge openings. 
•  Prevent manual intervention by using suitable measures, e.g. appropriate housings or a 
protective grating.