04/2005 Electro-Magnetic Compatibility (EMC)
SINAMICS G110 Operating Instructions
6SL3298-0AA11-0BP0
75
9.1.4 Three general cases of EMC performance are applicable
as detailed below
Case 1: General Industrial
Compliance with the EMC Product Standard for Power Drive Systems EN 61800-3
for use in Second Environment (Industrial) and Restricted Distribution.
Table 9-2 Case 1 - General Industrial
EMC Phenomenon Standard Level
Radiated Emissions EN 55011 Level Group 1, Class A
Emissions
Conducted Emissions EN 61800-3 Limits are equivalent to EN55011, Class A,
group 2
Electrostatic Discharge EN 61000-4-2 8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables (Level 3), 1 kV control
(Level 3)
Immunity:
Radio Frequency
Electromagnetic Field
EN 61000-4-3 26-1000 MHz, 10 V/m
Case 2: Filtered Industrial
This level of performance will allow the manufacturer/assembler to self-certify their
apparatus for compliance with the EMC directive for the industrial environment as
regards the EMC performance characteristics of the power drive system.
Performance limits are as specified in the Generic Industrial Emissions and
Immunity standards EN 50081-2 and EN 61000-6-2.
Table 9-3 Case 2 - Filtered Industrial
EMC Phenomenon Standard Level
Radiated Emissions EN 55011 Level Group 1, Class A
Emissions:
Conducted Emissions EN 61800-3
Limits are equivalent to EN55011, Class A,
group 2
Supply Voltage Distortion EN 61000-2-4
Voltage Fluctuations, Dips,
Unbalance, Frequency
Variations
EN 61000-2-1
Electrostatic Discharge EN 61000-4-2 8 kV air discharge
Burst Interference EN 61000-4-4
2 kV power cables (Level 3), 2 kV control
(Level 4)
Immunity:
Radio Frequency
Electromagnetic Field,
amplitude modulated
EN 61000-4-3
80-1000 MHz, 10 V/m, 80% AM, power and
signal lines