6.9 Direct setpoint input (MDI)
Description
For direct setpoint input (MDI, Manual Data Input), a higher-level control provides the converter
with the position setpoint and traversing pro󹪝le.
Example 1
The higher-level control speci󹪝es the value of the setpoint either as a relative or an absolute
position setpoint:
3RVLWLRQVHWSRLQWUHDFKHG
3RVLWLRQLQJW\SH
DEVROXWH
UHODWLYH
6HWSRLQWDFFHSWDQFHHGJH
212))
W
V
W
W
Y
W
V
Figure 6-20 Position axis with direct setpoint input (MDI)
Example 2
The higher-level control selects the mode "Set-up":
'LUHFWLRQVHOHFWLRQ
'LUHFWLRQVHOHFWLRQ
6HWWLQJXSVHOHFWLRQ
$[LVPDLQWDLQV
LWVSRVLWLRQ
6HWSRLQWWUDQVIHU
212))
W
Y
W
Figure 6-21 Set up axis with direct setpoint input (MDI)
Commissioning
6.9 Direct setpoint input (MDI)
Basic positioner
88 Function Manual, 09/2020, FW V4.7 SP13, A5E34257659B AG