What to do if my Siemens DC Drives show alarms A05000 A05001 A05002 A05004 A05006?
I
Ian HooverAug 29, 2025
If you see alarms A05000, A05001, A05002, A05004, and A05006, verify the following:
- Is the ambient temperature within the defined limit values?
- Are the load conditions and duty cycle configured accordingly?
- Has the cooling failed?
M
Mark JohnsonSep 5, 2025
What to do if Siemens DC Drives display alarm A03520?
J
jeffrey37Sep 5, 2025
If alarm A03520 appears, check that the sensor is connected correctly.
R
richard09Aug 28, 2025
How to fix F07016 Motor temperature sensor fault on Siemens Inverter?
D
davistraceyAug 28, 2025
To resolve the F07016 Motor temperature sensor fault on your Siemens Inverter, make sure that the sensor is connected correctly and check the parameterization (p0601).
A
Adam BennettSep 23, 2025
What causes A07805 Drive Power unit overload I2t on Siemens SINAMICS G120C?
C
cervantesharoldSep 23, 2025
To address the A07805 Drive: Power unit overload I2t on your Siemens Inverter, reduce the continuous load.
T
Tammy MooreSep 6, 2025
What to do if Siemens DC Drives display fault F01600?
R
Rachael WagnerSep 6, 2025
If fault F01600 occurs, select STO and then deselect it again.
J
Jesse BaileySep 9, 2025
What to do if Siemens Inverter shows F01001 FloatingPoint exception?
C
Cynthia RobinsonSep 9, 2025
To resolve the F01001 FloatingPoint exception on your Siemens Inverter, switch off the inverter and switch it on again.
V
vmarksSep 13, 2025
How to troubleshoot F07860 External fault 1 on Siemens SINAMICS G120C?
S
seanfloresSep 13, 2025
To resolve the F07860 External fault 1 error on your Siemens Inverter, remove the external causes for this fault.
J
Jerome BellSep 23, 2025
How to resolve F07426 Technology controller actual value limited on Siemens SINAMICS G120C Inverter?
J
Jacob MaySep 23, 2025
To resolve the F07426 Technology controller actual value limited error on your Siemens Inverter, adapt the limits to the signal level.
Z
Zoe LewisAug 26, 2025
What causes F07011 motor overtemperature fault on Siemens SINAMICS G120C?
E
Elizabeth RobertsAug 26, 2025
If your Siemens Inverter displays the F07011 motor overtemperature fault, reduce the motor load, check the ambient temperature, and inspect the sensor's wiring and connection.
V
Victor SantanaAug 25, 2025
How to resolve F30002 DC-link voltage overvoltage on Siemens SINAMICS G120C Inverter?
E
Elizabeth GatesAug 26, 2025
To resolve the F30002 DC-link voltage overvoltage error on your Siemens Inverter, increase the ramp-down time (p1121), set the rounding times (p1130, p1136), and activate the DC-link voltage controller.
Siemens SINAMICS G120C Specifications
General
Communication Interfaces
PROFINET, PROFIBUS, USS, Modbus RTU
Protection Class
IP20
Ambient Temperature
-10°C to +50°C
Storage Temperature
-40°C to +70°C
Power Range
0.55 kW to 132 kW
Voltage Range
380 V to 480 V
Output Voltage
0 V to Supply Voltage
Frequency Range
0 Hz to rated output frequency
Control Modes
Vector control with encoder
Protection
Overload, overvoltage, undervoltage, short circuit, ground fault