How to fix A50010 PROFINET name of station invalid on Siemens SINAMICS G120C Inverter?
V
Virginia GonzalezSep 23, 2025
To resolve the A50010 PROFINET name of station invalid error on your Siemens Inverter, correct the name of station (p8920) and activate (p8925 = 2).
C
Cory AlexanderAug 31, 2025
What to do if Siemens DC Drives display fault F06310?
A
Ashley MorrisAug 31, 2025
If fault F06310 is displayed, check the parameterized supply voltage and change it if required (p0210). Also, check the line voltage.
A
Alicia RodriguezAug 25, 2025
What to do if Siemens SINAMICS G120C shows F07801 motor overcurrent error?
S
Sarah MartinezAug 25, 2025
To address the F07801 motor overcurrent issue in your Siemens Inverter, check the current limits (p0640). If using V/f control, inspect the current limiting controller (p1340 … p1346).
V
Victor SantanaAug 25, 2025
How to resolve F30002 DC-link voltage overvoltage on Siemens SINAMICS G120C Inverter?
E
Elizabeth GatesAug 26, 2025
To resolve the F30002 DC-link voltage overvoltage error on your Siemens Inverter, increase the ramp-down time (p1121), set the rounding times (p1130, p1136), and activate the DC-link voltage controller.
Z
Zoe LewisAug 26, 2025
What causes F07011 motor overtemperature fault on Siemens SINAMICS G120C?
E
Elizabeth RobertsAug 26, 2025
If your Siemens Inverter displays the F07011 motor overtemperature fault, reduce the motor load, check the ambient temperature, and inspect the sensor's wiring and connection.
H
Heather MckenzieAug 26, 2025
How to troubleshoot F30003 DC-link voltage undervoltage on Siemens Inverter?
B
Bethany HerreraAug 26, 2025
To resolve the F30003 DC-link voltage undervoltage fault in your Siemens Inverter, check the line voltage (p0210).
E
Ethan ArmstrongAug 27, 2025
Why is my Siemens SINAMICS G120C showing F30004 inverter overtemperature?
E
Emily ArmstrongAug 27, 2025
If your Siemens Inverter displays the F30004 inverter overtemperature fault, check whether the inverter fan is running.
G
Gary SawyerAug 27, 2025
What to do if Siemens SINAMICS G120C Inverter displays F07900 motor blocked fault?
M
Maxwell HuertaAug 27, 2025
If your Siemens Inverter displays the F07900 motor blocked fault, ensure that the motor can rotate freely.
K
kimjasonAug 27, 2025
How to fix F01662 CU hardware fault on Siemens SINAMICS G120C?
M
Michael NicholsAug 27, 2025
To resolve the F01662 CU hardware fault on your Siemens Inverter, switch off the inverter and switch it on again, upgrade the firmware, or contact technical support.
B
brentjohnsonAug 28, 2025
What to do if Siemens SINAMICS G120C Inverter displays F01250 CU hardware fault?
S
Stephanie StricklandAug 28, 2025
To resolve the F01250 CU hardware fault on your Siemens Inverter, replace the inverter.
Siemens SINAMICS G120C Specifications
General
Communication Interfaces
PROFINET, PROFIBUS, USS, Modbus RTU
Protection Class
IP20
Ambient Temperature
-10°C to +50°C
Storage Temperature
-40°C to +70°C
Power Range
0.55 kW to 132 kW
Voltage Range
380 V to 480 V
Output Voltage
0 V to Supply Voltage
Frequency Range
0 Hz to rated output frequency
Control Modes
Vector control with encoder
Protection
Overload, overvoltage, undervoltage, short circuit, ground fault