Technical data
7.6 Technical data, 400 V inverters
Power Module PM240-2
80 Hardware Installation Manual, 01/2017, A5E33294624B AE
Short-circuit current rating
(SCCR) and branch protec-
tion
≤ 100 kA rms
Branch protection and short-circuit strength according to UL and IEC
(https://support.industry.siemens.com/cs/ww/en/view/109479152)
Braking methods DC braking, compound braking, dynamic braking with integrated braking chopper
Degree of protection ac-
cording to EN 60529
IP20
IP55 PT devices outside the control cabinet
Protection class according
The inverters are devices with protection class I
Touch protection according
DGUV regulation 3 when used for the intended purpose
Cooling in compliance with
Forced air cooling AF
Dependent on the input voltage and output power