Commissioning
4.18 Fine calibration and tuning
Hydraulic Drive
104 System Manual, 04/2015, 6SL3097-4BA00-0BP1
4.18
Fine calibration and tuning
4.18.1
Calibration
The following requirements must be satisfied before the three calibrations are performed:
Position calibration
The axis must be referenced and the piston must be at position A.
Pressure calibration
The system must be in a no pressure state.
Valve offset calibration
The axis must be in closed-loop controlled operation.
Figure 4-37 Calibration required
To perform the calibrations, press the "Position calibration", "Pressure calibration" and
"Valve offset calibration" softkeys in this sequence. The progress of the respective
calibration is displayed. The dialog looks like this once all 3 calibration types have been
carried out.