EasyManua.ls Logo

Siemens SINAMICS S120 - System Data; Climatic and Mechanical Environmental Conditions in Operation

Siemens SINAMICS S120
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System overview
2.4 System data
Hydraulic Drive
32 System Manual, 04/2015, 6SL3097-4BA00-0BP1
2.4
System data
2.4.1
Climatic and mechanical environmental conditions in operation
Note
The following information refers to the electrical section of the HLA module, however, not to
external hydraulic components.
Climatic environmental conditions
If the specified values cannot be maintained, then a heat exchanger or air conditioner must
be provided.
Table 2- 3 Environmental conditions
Degree of protection
IP20 according to EN 60529
Climatic environmental conditions
Long-term storage in the transport
packaging
Class 1K4 acc. to EN 60721-3-1
Temperature: -25 +55 °C
Transport in the transport packaging Class 2K4 acc. to EN 60721-3-2
Temperature: -40 +70 °C
Operation Temperature: 0 … +55 °C
1)2)
Relative humidity: 5 95 %
Oil mist, salt mist, ice formation, condensation, drip-
ping water, spraying water, splashing water and water
jets are not permitted
1)
Current derating above 40 °C at the output of the servo solenoid valve
2)
At altitudes exceeding 1500 m above sea level, the upper temperature limit must be reduced by
3.5 °C / 500 m.
Mechanical environmental conditions
Classification using 3M1 according to IEC 60721-3-X.
Note
The limi
t values (test values) listed in the standards are not permissible as continuous load.

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals