Drive functions
5.8 Cylinder drive
Hydraulic Drive
182 System Manual, 04/2015, 6SL3097-4BA00-0BP1
5.8
Cylinder drive
Cylinder data
In addition to the piston diameter (p0310), the rod diameter at the A and B sides (p0311,
p0312) must be entered. For a differential cylinder, both rod diameters are different, one of
the rods might even have a zero diameter. The maximum piston stroke (p0313) and the
cylinder dead volume (p0314, p0315) are also required.
The cylinder dead volume is the liquid volume between the cylinder and servo solenoid valve
which cannot be displaced by the piston.
The dead volume attributable to the pipework is separately parameterized (p0346 to p0348).
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p0310[0...n]
Cylinder piston diameter
p0311[0...n]
Cylinder p
iston rod diameter A side
p0312[0...n]
Cylinder piston rod diameter B side
p0313[0...n]
Piston stroke
p0314[0...n]
Cylinder dead volume A side
p0315[0...n]
Cylinder dead volume B side
p0346[0...n]
Line length A side
p0347[0...n]
Line length B side
p0348[0...n]
Internal line diameter