Commissioning
4.16 Importing valve lists
Hydraulic Drive
78 System Manual, 04/2015, 6SL3097-4BA00-0BP1
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p2000
Reference velocity
p2001
Reference voltage
p2002
Reference pressure
p2003
Reference force
p2004
Reference power
p2005
Reference angle
p2006
Referen
ce temperature
p2007
Reference acceleration
4.16
Importing valve lists
You can import a list with suitable valves as follows:
1. Select the "System data" softkey from the "Basic commissioning menu".
2. In the following "System data" dialog, select entry "HMI data > Data backup > IB data".
3. You can access the "Machine data loaded" dialog using the "Manage data" softkey.
Figure 4-21 Loading machine data
4. Select the "Import SINAMICS lists" option and press the "OK" softkey.
5. Select the valve list in the following "Import SINAMICS list" dialog. Import the selected list
using the "OK" softkey.