Drive functions
5.9 Drive data
Hydraulic Drive
184 System Manual, 04/2015, 6SL3097-4BA00-0BP1
Figure 5-19 Mounting position of the drive referred to the A side
The drive is approximated as a PT2 low-pass filter for the purpose of dimensioning the
closed-loop velocity control. The characteristic values "natural frequency" and "damping" are
calculated and preset from other drive data by the "Calculate drive model data" function.
p0345 can be set to specify the degree of damping to be applied when calculating the control
loop for "Calculate controller data".
Slow control loop, which only has a low amount of overshoot
Fast control loop, which has a higher tendency to overshoot
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p0340
Automatic parameter calculation
p0341[0...n]
p0343[0...n]
Valve/cylinder configuration
p0344[0...n]
Cylinder mounting position A side
p0345[0...n]
Required damping controlled axis
p0346[0...n]
p0347[0...n]
p0348[0...n]
p0350[0...n]
Damping uncontrolled axis
p0351[0...n]
Piston position natural frequency minimum
p0352[0...n]
al frequency A side
p0353[0...n]
Axis natural frequency center
p0354[0...n]
Axis natural frequency B side
p1532[0...n]
CO: Force offset, force limit