Drive functions
5.13 Monitoring functions
Hydraulic Drive
System Manual, 04/2015, 6SL3097-4BA00-0BP1
197
The pressure as process variable is to be monitored, whereby a temporary overpressure is
tolerated. For this, the output signal of an external sensor is connected with the variable
signaling function. The pressure thresholds and a pull-in delay are set as tolerance time.
When the output signal of the variable signaling function is set, bit 5 in message word
"MELDW" is set during cyclic communication. The "MELDW message word is part of
telegram 166 to be used for the HLA.
Figure 5-23 Variable signaling function
Function diagrams (see SINAMICS S120/S150 List Manual)
5301
- variable signaling function
Overview of important parameters (see SINAMICS S120/S150 List Manual)
p3290
ling function, start
p3291
CI: Variable signaling function signal source
r3294
BO: Variable signaling function, output signal
p3295
Variable signaling function, threshold value
p3296
Variable signaling function, hysteresis
p3297
ction, pickup delay
p3298
Variable signaling function, dropout delay
p3299
Variable signaling function, sampling time