A.3 Hydraulic
Hydraulic Drive
246 System Manual, 04/2015, 6SL3097-4BA00-0BP1
Valve amplifier
The functions of the integral valve amplifier utilize analog electronics, and are illustrated in
the following block diagram.
The main functions include:
Supply and evaluation of the position sensor (AC/DC converter)
Comparison of the setpoint input signal with valve spool actual value
Formation of manipulated variable via a PID controller for the output stage
Clocked output stage with pulse length modulation
The amplifier is calibrated to match the valve at the factory. The zero point is adjusted at the
NC when the system is being commissioned.
Figure A-14 Valve amplifier: Block diagram of directly controlled servo solenoid valves