EasyManua.ls Logo

Siemens SINAMICS S120 - Page 40

Siemens SINAMICS S120
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuration
3.3 Configuring the hydraulics
Hydraulic Drive
40 System Manual, 04/2015, 6SL3097-4BA00-0BP1
Flow rate characteristic, linear/with transition point
Valves with either a linear characteristic or with transition point characteristic can be
selected. Valves with a characteristic with a transition point are suitable for obtaining a
higher resolution in the low signal range (machining) and sufficient flow rate in the high
signal range (rapid traverse).
The definition of the transition point position as 40 % or 60 % means that only 10% of the
nominal opening cross-section (nominal flow rate) is released for 40 % or 60 % of the
nominal control signal (i.e. at U=4 V or 6 V).
The valve characteristic with transition point must be linearized in the HLA module to adapt it
to the closed-loop control of the entire drive (cylinder).
Figure 3-2 Diagram of a servo solenoid valve characteristic with transition point and its
compensation in the HLA module
Note
Recommended selection
Servo solenoid valves are generally recommended for applicatio
ns where there is a clear
separation between machining operation and rapid traverse.

Table of Contents

Other manuals for Siemens SINAMICS S120

Related product manuals