EasyManua.ls Logo

Siemens SINAMICS V20 - Page 211

Siemens SINAMICS V20
426 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter list
8.2 Parameter list
SINAMICS V20 Converter
Operating Instructions, 10/2019, A5E34559884-012
209
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data set
Data
type
Acc.
Level
P0199
Equipment system
number
0 - 65535 0 U, T - - U16 2
Specifies the unique equipment system number for the converter.
P0201[0...2]
Actual power module
code number
0 - 65535 0 T - - U16 3
Identifies hardware variant.
Index:
[0]
Converter code
[1]
Functionality version - last digit of the article number
[2]
Last used converter ID
Notice:
Parameter P0201 = 0 indicates that no power module has been identified.
r0204
Power module fea-
tures
- 0 - - - U32 3
Displays hardware features of power module.
Bit
Signal name
1 signal
0 signal
00
DC input voltage
Yes
No
01
RFI filter
Yes
No
02
Active line module
Yes
No
03
SLM
Yes
No
04
BLM with thryistor
Yes
No
05
BLM with diode
Yes
No
06
Water cooled
Yes
No
07
F3E converter
Yes
No
12
Safe brake
Yes
No
13 Safety enabled Yes No
14
Integrated output filter
Yes
No
Note:
Parameter r0204 = 0 indicates that no power module has been identified.