Parameter list
8.2 Parameter list
SINAMICS V20 Converter
224 Operating Instructions, 10/2019, A5E34559884-012
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
P0701[0...2]
Function of digital input 1
0 - 99
0
T
-
CDS
U16
2
Selects function of digital input 1.
0
Digital input disabled
1 ON/OFF1
2
ON reverse/OFF1
3
OFF2 - coast to standstill
4
OFF3 - quick ramp-down
5
ON/OFF2
9
Fault acknowledge
10
JOG right
11
JOG left
12
Reverse
13
MOP up (increase frequency)
14
MOP down (decrease frequency)
15
Fixed frequency selector bit0
16
Fixed frequency selector bit1
17
Fixed frequency selector bit2
18
Fixed frequency selector bit3
22
QuickStop Source 1
23
QuickStop Source 2
24
QuickStop Override
25
DC brake enable
27
Enable PID
29
External trip
33
Disable additional freq setpoint
99
Enable BICO parameterization
Dependency:
Resetting 99 (enable BICO parameterization) requires:
P0700 command source or
P0010 = 1, P3900 = 1, 2 or 3 (quick commissioning) or
P0010 = 30, P0970 = 1 factory reset in order to reset
Note:
"ON/OFF1" can only be selected for one digital input (e.g. P0700 = 2 and P0701 = 1). Configuring DI2
with P0702 = 1 will disable digital input 1 by setting P0701 = 0. Only the last activated digital input serves
as a command source. "ON/OFF1" on a digital input can be combined with "ON reverse/OFF1" on another
digital input.
P0702[0...2]
Function of digital input 2
0 - 99
0
T
-
CDS
U16
2
Selects function of digital input 2.
See P0701.
P0703[0...2]
Function of digital input 3
0 - 99
9
T
-
CDS
U16
2
Selects function of digital input 3.
See P0701.