Parameter list
8.2 Parameter list
SINAMICS V20 Converter
332 Operating Instructions, 10/2019, A5E34559884-012
Parameter
Function
Range
Factory
default
Can be
changed
Scaling
Data
set
Data
type
Acc.
Level
P7844
Acceptance test, con-
firmation
0 - 2 0 T - - U16 3
After an automatic download from the SD card at startup, this parameter will be automatically set to 1. Also
a fault F395 will be set.
With setting to P7844 = 0 you quit F395 and confirm the parameter settings. Setting this parameter to 2 is
only possible if an automatic download has been performed at startup. In this case the download will be
undone and the previously stored parameters will be enabled.
0
Acceptance test/confirmation OK
1
Acceptance test/confirmation is pending
2
Undo clone
Note:
If no automatic download from the SD card has been performed during startup the setting 2 is not possible.
If the clone file contains user defaults and the cloning at startup is rejected with P7844 = 2, parameters are
set to the user defaults in the clone file instead of the previously saved values.
P8458
Clone control
0 - 4
2
C, T
-
-
U16
3
This parameter specifies whether a cloning at startup will be performed. The File clone00.bin will be used.
If no SD card is inserted there will be a normal startup.
0
No startup cloning
1
Clone at startup once
2
Clone at startup always
3
Clone at startup once, except the motor data
4
Clone at startup always, except the motor data
Note:
Default value is 2. After first cloning the parameter is set to 0. If an SD card is inserted without a valid file
the converter will set a fault F61/F63/F64 which can only be cleared by a power-cycle. The fault is signaled
by a flashing RUN LED (Commissioning). The SF LED is not activated. P8458 will not be changed by per-
forming a factory reset.
P8553
Menu type
0 - 1
0
U, T
-
-
U16
1
Selects whether to have menus with no text or menus with some text on the BOP.
0
Menus with no text
1
Menus with some text