43
Maximum motor cable lengths
Converter vari-
ant
Maximum cable length
EMC compliant
Without output reactor
With output reactor
400 V
With integrated
EMC filter
1)
With external
line filter
2)
Unshielded
Shielded
Unshielded
Shielded
FSA
10 m
25 m
50 m
25 m
150 m
150 m
FSB to FSD
25 m
25 m
50 m
25 m
150 m
150 m
FSE
50 m
25 m
100 m
50 m
300 m
200 m
230 V
With integrated
EMC filter
With external
line filter
Unshielded
Shielded
Unshielded
Shielded
FSAA/FSAB
5 m
3)
5 m
3)
50 m
25 m
200 m
200 m
FSAC
10 m
3)
10 m
2)
50 m
25 m
200 m
200 m
FSAD
5 m
3)
, 25 m
2)
5 m
3)
50 m
25 m
200 m
200 m
FSC
25 m
2)
5 m
3)
50 m
25 m
200 m
200 m
1)
EMC (RE/CE C3) compliant, second environment (industrial area). RE/CE C3 refers to EMC compliance to EN61800-3
Category C3 (level equivalent to EN55011, Class A2) for Radiated and Conducted Emissions.
2)
EMC (RE/CE C2) compliant, first environment (residential area). RE/CE C2 refers to EMC compliance to EN61800-3
Category C2 (level equivalent to EN55011, Class A1) for Radiated and Conducted Emissions. See Section B.1.7 for the
specifications of external line filters.
3)
EMC (RE/CE C1) compliant, first environment (residential area). RE/CE C1 refers to EMC compliance to EN61800-3
Category C1 (level equivalent to EN55011, Class B) for Radiated and Conducted Emissions.
Star-delta connection of the motor
Select delta connection under one of the following conditions:
a 230 V/400 V motor (operating at 87 Hz instead of 50 Hz) on a 400 V converter