6.3 PLC user program for turning (UPGMTURN)
6-144
SINUMERIK 802S
6FC5 597–2AA00–0BP2 (01.02)
[4] O 0.7 O 0.6 O 0.5 O 0.4 O 0.3 O 0.2 O 0.1 O 0.0
Output valid
[5] O 1.7 O 1.6 O 1.5 O 1.4 O 1.3 O 1.2 O 1.1 O 1.0
Output 0-active
[6] O 0.7 O 0.6 O 0.5 O 0.4 O 0.3 O 0.2 O 0.1 O 0.0
Output 0-active
[7] O 1.7 O 1.6 O 1.5 O 1.4 O 1.3 O 1.2 O 1.1 O 1.0
MCP customer key valid
[8] K7 K6 K5 K4 K3 K2 K1 K0
MCP customer key valid
[9] K9 K8
Rotation monitoring active
[10] Z axis X axis
Machine configuration
[11] Override
active
Key
assignment
X axis
Input valid: 0 - demask input not used
1 - input is used
Output valid: 0 - demask output not used
1 - output is used
Input / output 0-active: 0 - All signals use positive logic as standard, i.e.
logic 1-active (24V).
1 - When connecting to systems with negative
logic, i.e. logic 0-active (0V).
MCP customer key valid: 0 - Demask MCP customer keys not used
1 - MCP customer key is used
Rotation monitoring active: 0 - Rotation monitoring function is not used
1 - Rotation monitoring is activated for the relevant axis (X, Z)
after referencing the axis. The UPGMTURN sets the Rotation Monitoring interface signal
(390x5000.0) (see ”Technical Manual: Rotation Monitoring of Step-Switching Motor with
BERO”)
Machine configuration: (bit0) key assignment X axis to MCP
0 – tool behind turning center
1 – tool ahead of turning center