22037 AUXFU_ASSIGN_SIM_TIME C04 H2, S1
- Acknowledgment time DWORD PowerOn
-
- 64 0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0, 0, 0, 0, 0, 0, 0,
0, 0, 0,, ...
0 0x7FFFFFF 2/2 M
Description: Acknowledgment time for auxiliary functions in ms.
See MD22010 $MC_AUXFU_ASSIGN_TYPE[n] (auxiliary function type)
22040 AUXFU_PREDEF_GROUP C04 H2
- Predefined auxiliary function groups DWORD PowerOn
-
- 301 1, 1, 1, 1, 1, 1, 2, 2, 2,
2, 2, 4, 4, 4, 4, 4, 4, 3,
1, 1, 1,, ...
0 168 2/2 M
Description: Group assignment of predefined auxiliary functions.
The predefined groups cannot be changed for indices 0, 1, 2, 3, 4, 22, 23, 24.
22050 AUXFU_PREDEF_TYPE C04 H2
- Predefined auxiliary function type STRING PowerOn
-
- 301 M, M, M, M, M, M, M,
M, M, M,M, M, M,, M,
M, M, M, M, M, M, M,
M...
- - 2/2 M
Description: The address codes of the predefined auxiliary functions are fix.
This setting cannot be changed!
22060 AUXFU_PREDEF_EXTENSION C04 H2
- Predefined auxiliary function extension DWORD PowerOn
-
- 301 0, 0, 0, 0, 0, 0, 1, 1, 1,
1, 1, 1, 1, 1, 1, 1, 1, 1,
0, 0, 0,, ...
-1 99 2/2 M
Description: Address extension for predefined auxiliary functions:
This setting can be changed only for indices 5 to 17 and 21!
22070 AUXFU_PREDEF_VALUE C04 H2
- Predefined auxiliary function value DWORD PowerOn
-
- 301 0, 1, 2, 17, 30, 6, 3, 4,
5, 19, 70, 40, 41, 42,
43, 44, 45, -1,...
- - 2/2 M
Description: Value of predefined auxiliary functions.
This setting cannot be changed!
Machine data
3.3 Channel-specific machine data
Parameter Manual