Loading...
... ...
1030 Hex value (BYTE)
1031 Hex value (BYTE)
6.10.3 FLOAT values (MD 14514 USER_DATA_FLOAT)
DB4500 Signals from NCK [r32]
NCK -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
2000 Float value (REAL/4 byte)
2004 Float value (REAL/4 byte)
2008 Float value (REAL/4 byte)
2012 Float value (REAL/4 byte)
2016 Float value (REAL/4 byte)
2020 Float value (REAL/4 byte)
2024 Float value (REAL/4 byte)
2028 Float value (REAL/4 byte)
6.10.4 User alarm: Configuring (MD 14516 USER_DATA_PLC_ALARM)
DB4500 Signals from NCK [r8]
NCK -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
3000 Alarm response/cancel criteria, alarm 700000
3001 Alarm response/cancel criteria, alarm 700001
3002 Alarm response/cancel criteria, alarm 700002
... ...
3247 Alarm response/cancel criteria, alarm 700247
Note
For more information about how to configure the user alarms, refer to the SINUMERIK 808D
ADVANCED Commissioning Manual.
PLC user interface
6.10 PLC machine data
Parameter Manual
482 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1