4
6
7
6.5.9 General selection/status signals from HMI (retentive area)
DB1900 Signals from HMI [r]
HMI -> PLC interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
1000
1001
1002
1003 Axis number for handwheel 1
Machine
axis
Handwheel
selected
Contour
handwheel
C B A
1004 Axis number for handwheel 2
Machine
axis
Handwheel
selected
Contour
handwheel
C B A
1005
1006
1007
6.5.10 General selection/status signals to HMI (retentive area)
DB1900 Signals to HMI [r/w]
PLC -> HMI interface
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
5000 OP key
block
5001
5002 Enable
measure‐
ment in
JOG
5003
5004 ...
5007
T-number for tool measurement in JOG (DINT)
5008 ...
5011
PLC user interface
6.5 Signals from/to HMI
Parameter Manual