Bit 16 - 19: Extension $AC_TOTAL_PARTS
-------------------------------------------------------------------------
Meaning of the bits 16-19 applies only if Bit4 =1 and $AC_REQUIRED_PARTS > 0:
Bit 16 = 0: $AC_TOTAL_PARTS is active in MDI mode
Bit 16 = 1: No machining $AC_TOTAL_PARTS in MDI mode
Bit 17 Reserved!
Bit 18 Reserved!
Bit 19 Reserved!
Bit 20 - 23: Extension $AC_ACTUAL_PARTS
-------------------------------------------------------------------------
Meaning of bits 20-23 only if bit8 =1 and $AC_REQUIRED_PARTS > 0:
Bit 20 = 0: $AC_ACTUAL_PARTS is active in MDI mode
Bit 20 = 1: No machining $AC_ACTUAL_PARTS in MDI mode
Bit 21 Reserved!
Bit 22 Reserved!
Bit 23 Reserved!
Bit 24 - 27: Extension $AC_SPECIAL_PARTS
-------------------------------------------------------------------------
Meaning of bits 24-27 only if bit12 =1 and $AC_REQUIRED_PARTS > 0:
Bit 24 = 0: $AC_SPECIAL_PARTS is active in MDI mode
Bit 24 = 1: No machining $AC_SPECIAL_PARTS in MDI mode
Bit 25 Reserved!
Bit 26 Reserved!
Bit 27 Reserved!
Related to:
MD27882 $MC_PART_COUNTER_MCODE
27882 PART_COUNTER_MCODE C09 K1
- Workpiece counting with user-defined M command BYTE PowerOn
-
- 3 2, 2, 2, 2, 2, 2, 2, 2, 2,
2, 2, 2, 2, 2, 2, 2, 2, 2,
2, 2, 2, 2...
0 99 3/2 M
Description: If part counting is activated via MD27880 $MC_PART_COUNTER, the count pulse can be
triggered by a special M command.
Only then are the values defined here taken into account:
Meaning:
The part counters are incremented by 1 in the NST signal output of the M command
described, where:
MD27882 $MC_PART_COUNTER_MCODE[0] for $AC_TOTAL_PARTS
MD27882 $MC_PART_COUNTER_MCODE[1] for $AC_ACTUAL_PARTS
MD27882 $MC_PART_COUNTER_MCODE[2] for $AC_SPECIAL_PARTS
27920 TIME_LIMIT_NETTO_INT_TASK EXP, C01 -
s Runtime limit of interpreter subtask DOUBLE PowerOn
-
- - 0.005, 0.005, 0.005,
0.005, 0.005, 0.005,
0.005, 0.005...
0.001 0.100 ReadOnly S
Machine data
3.3 Channel-specific machine data
Parameter Manual
196 Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1

Table of Contents

Other manuals for Siemens SINUMERIK 808D ADVANCED

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK 808D ADVANCED and is the answer not in the manual?

Siemens SINUMERIK 808D ADVANCED Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK 808D ADVANCED
CategoryControl Unit
LanguageEnglish

Related product manuals