379 SPINDLE_DISP_MODE - -
- Spindle display mode BYTE Immediately
-
- 0 0 0 2 3/3 U
Description: 0: Standard Mode; spindle speed display
1: Constant cutting speed display when G96 is set
2: Mixed display
383 V24_PPI_ADDR_DRV1 - -
- Station address Drives BYTE PowerOn
-
- 0 5 0 126 3/3 U
Description: Station address Drives
386 USER_CLASS_WRITE_CMA_DIR - -
- Defines the access level for the CMA directory in the NCK BYTE Immediately
-
- - 7 1 7 2/2 M
Description: Defines the access level for the CMA directory in the NCK
391 DISPLAY_MODE_INDEXING_AXIS - -
- Defines the display format of an indexing axis. DWORD Immediately
-
- - 0 0 1 7/2 M
Description: Defines the display format of an indexing axis.
0 = indexing position
1 = type-spec. actual value
392 USER_CLASS_WRITE_LOC_NO - -
- Access authorization for writing the location number into the tool
list
BYTE Immediately
-
- - 7 0 7 3/2 M
Description: Defines the access authorization for writing the location number in the tool list
395 COL_OVERSIZE_TYPE_CHECKBOX - -
- Check box in tool list BOOLEAN Immediately
-
- - 1 0 1 3/3 U
Description: Check box in tool list
9000 SCREEN_SAVER_WAIT_TIME - -
s The time wait for switch to screen save. DWORD PowerOn
-
- - 3600 0 36000 1/1 M
Description: The time wait for switch to screen save.
Machine data
3.1 Display machine data
Parameter Manual
Parameter Manual, 08/2015, 6FC5397-8EP40-0BA1 31